Features
Features
● Auto switch 4 FUN: DC to AC, AC bypass, AC charger, and UPS
● Built-in AC charger,75A max, adjustable
● Pure sine wave output, input & output fully isolation
● 5 LED display working, Digital LCD display data info
● Input: Utility AC or Generator etc
● Start Auto restart while AC is recovering (optional)
● Output AVR: stabilized AC voltage RMS (optional)
● Excellent loads with 3*rated start power
● Input polarity/UVP/OVP/OSP/OLP/OTP
● AC with Circular Electric Connector, Hot Plugging DC Connectors
● Communication Port: RS-232
Specification
| Models |
SPR3000-112 |
SPR3000-124 |
SPR3000-148 |
SPR3000-212 |
SPR3000-224 |
SPR3000-248 |
| output power |
3000W |
| SurgePower |
9000W |
| DCInputVoltage |
12VDC |
24VDC |
48VDC |
12VDC |
24VDC |
48VDC |
| OutputVoltage |
100/110/120VAC±5% |
220/230/240VAC±3% |
| OutputFrequency |
50/60Hz±0.5% |
| OutputWaveform |
Truesinewave(THD<5%) |
| power factor |
0.1~1 |
| Efficiency |
88% |
89% |
91% |
89% |
90% |
93% |
| NoLoadPower |
<10W(Powersavingmode) |
| transfer time |
<8ms |
| ACRange |
184-253VAC(176-276VAC)/154-253VAC(150-276VAC) |
| AVROutput(optional) |
120VAC±10% |
230VAC±10% |
| DCRange |
10.0~15.5VDC,*2for24VDC,*4for48VDC |
| ChargeCurrent |
80A |
40A |
25A |
75A |
45A |
30A |
| Safety |
UL458 |
LVD(EN60950) |
| EMC |
FCCPart15ClassA |
| operating temp |
-20~50℃ |
| WorkingHumidity |
20~90%RH |
| StorageTemp |
-30~70℃ |
| Cooling |
Automaticallycontrolledcoolingfan |
| Weight(kg) |
30 |
| Size(mm) |
19inch,2UStandardcabinet,482*400*132mm(L*W*H) |
| Application |
SpecialVechile,Yacht,airborne,Communicationfieldetc. |